hneSysSyncSecondaryRefLineState OBJECT-TYPE
SYNTAX INTEGER { unknown(0),
valid(1),
lossOfSignalError(2),
frequencyOffsetError(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the state of the secondary reference
line termination point (SONET line) to be used as a timing
source by the sync module. This object is relevant if the
'hneSysSyncTimingMode' is set to 'line' and the
'hneSysSyncPrimaryRefLine' is configured.

unknown(0) - the state of the line has not been
determined.
valid(1) - the line is operating within
frequency specification.
lossOfSignalError - loss of signal was detected from the
line and has failed the health check.
frequencyOffsetError - frequency errors were detected from
the line and has failed the health check"