Description:
|
salixAtmfM4PlugInUnitRedundancyPartnerModule OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When retrieved, this attributes represents the current
partner module of a pair of plugins that are in redundancy
relationship. This attribute is only valid when the
'salixAtmfM4PlugInUnitRedundancyConfig' attribute is set to
either 'working' or 'protect'.
Writing to this object can either create a redundancy pair
(if one doesn't already exist) or can cause a manual
changeover of the working module (if there is a new value
written).
NOTE: It is only necessary to set the information on one of
plug-in units entries. The information will be
automatically set in the other entry by the system."
|
|
|
|
|
|