Description:
|
salixSysSyncForcedState OBJECT-TYPE
SYNTAX INTEGER { none(0),
revertiveSwitchInhibit(1),
autoReferenceSwitchInhbit(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the state of the sync module with
regard to switching between the configured active reference,
the value of the 'salixSysSyncConfiguredActiveRef' variable, and
the alternate active reference. The alternate active
reference is identified by the 'salixSysSyncPrimaryRef' or
'salixSysSyncSecondaryRef' that is not configured as the
'salixSysSyncConfiguredActiveRef'.
none(0) - the sync module is in a state where it is free
to switch between the configured active reference
the alternate active reference.
revertiveSwitchInhibit - the state of the sync module after
switching from the 'salixSysSyncConfiguredActiveRef'
to the 'salixSysSyncCurrentActiveRef' when the
'salixSysSyncRevertiveSwitch' is configured as 'false'.
In this state the sync module will not revert back
to using the 'salixSysSyncConfiguredActiveRef' unless
the 'salixSysSyncCurrentActiveRef' has failed and the
state of the active reference defined by the
'salixSysSyncConfiguredActiveRef' variable is 'valid'.
autoReferenceSwitchInhibit - the state of the sync module when
the 'salixSysSyncAutoReferenceSwitch' variable is
configured as 'false'. In this state the sync module
will not switch to using the alternate active reference
unless the 'salixSysSyncCurrentActiveRef' has failed and
the state of the alternate active reference is 'valid'."
|
|
|
|
|
|