Description:
|
scfSystemAmbientTemperatureMinPollingInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum interval time in seconds between updates of
scfSystemAmbientTemperatureValue. It is strongly
recommended to get object scfSystemAmbientTemperatureValue
with intervals longer than this value. It is meaningless to
get value at smaller intervals, because, internally,
scfSystemAmbientTemperatureValue will not be updated.
When this feature is not supported, maximum