Description:
|
hwXponOntEthPortPoePowerDetectionStatus OBJECT-TYPE
SYNTAX INTEGER {noneed(1), searching(2), delivering(3), forced(4), fault(5), specificFault(6), invalid(-1)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the power detection status of the ONT Ethernet port.
Options:
1. noneed(1) - Indicates that the ONT Ethernet port does not need to supply power to the PD.
2. searching(2) - Indicates that the ONT Ethernet port is in the power supply searching state.
3. delivering(3) - Indicates that the ONT Ethernet port is in the power supply delivering state.
4. forced(4) - Indicates that the ONT Ethernet port is in the forced power supply state.
5. fault(5) - Indicates that the ONT Ethernet port is in the forced power supply failure state.
6. specificFault(6) - Indicates that the ONT Ethernet port is in the power supply failure state because the PD does not meet the current power supply conditions.
7. invalid(-1) - Indicates that the query fails or no information is detected."
|
|
|