Description:
|
pm200fr20CntclientInputErrorCounterValuePortn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Client Input Errors :This counter
is increased each time a 10b/8b
running disparity error is detected
on the Client input stream <Help>
This counter gives the number
of errors on the client port (FCS
errors for 10GbE and BIP8 errors