Description:
|
pme1008CtrlaccessLoopPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Client Facility Loopback :This
OID, when set at '1' puts the client
port in loopback, looping the received
10 Gb/s signal on the transmit
10 Gb/s output. <Help> This control
enables the Out Loopback on the
client port, looping the client
input signal on the client output"
|
|
|