Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 20044 modulePm20020ma(69) pm20020maalarms(2) pm20020maAlmOther(1) pm20020maAlmOtherCrit(3) pm20020maAlmmsaNetworkTxAlignment(81) pm20020maAlmNetTxCmuLockFault(14)}

pm20020maAlmNetTxCmuLockFault(14)

 
 

OID description



 
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

pm20020maAlmNetTxCmuLockFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line Trscv Network Tx CMU Lock
Fault :This OID indicates a Tx
Clock Multiplier Unit Lock Fault
is detected on the Line Trscv Network
interface <Help> Alarm indicating
a Tx Clock Multiplier Unit Lock
Fault is detected on the Line Trscv
Network interface <Condtype> NET_TX_CMU_LOCK_FAULT
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)"



Classification:

MIB object for network management

 
See classes of OIDs
 
 
Short link: