Description:
|
pm1001pcAlmLineTecFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line Optical Tx Temp Regul. Failed
:This OID indicates a failure on
the TEC module <Help> This alarm
indicates if the TEC of the line
transceiver is in fail condition
<Condtype> LINE_TEC_FAULT <Probcause>
transmitterFailure (56) <Alarmtype>