Description:
|
pm1001pcAlmClientTxBiasHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Client Transceiver Bias High Warning
:Warning indicating that the XFP/OTX
transmitter laser bias current
is higher than the threshold value
written in the XFP EEPROM <Condtype>
CLIENT_TX_BIAS_HIGH_WARNING <Probcause>
transmitterFailure (56) <Alarmtype>