Description:
|
pm1001lhAlmLineLaserTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line Laser Temp. High Warning
:Warning indicating the Line OTX
TLH laser temperature is higher
than the threshold written in the
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_WARNING
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)"
|
|
|