transferResult OBJECT-TYPE
SYNTAX INTEGER {not-initialized(1), transfer-successful(2), upload-in-progress(3), download-in-progress(4), generic-error(5), no-response-from-host(6), connection-lost(7), file-not-found(8), file-empty(9), file-too-big(10), access-rights-violation(11), invalid-file-header(12), checksum-error(13), transfer-error(14), hardware-error(15), file-already-exists(16), config-unreadable-version(17), config-file-empty(18), config-impossible(19), config-internal-error(20), config-applied-ok(21)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The result of the latest file transfer.
When one of the TFTP variables is modified, this
variable is reset to not-initialized.
When a configuration file is downloaded, the content of
the configuration file is checked. If the file is valid
and if a reset is mandatory then the atm subsystem is
reset automatically.
If the configuration file is not valid or if a reset
is not required, the following values are returned in
transferResult:
- config-unreadable-version: the control point
does not support the version of configuration file.
This configuration file has probably been built
by a further version of control point.
- config-file-empty: the configuration file is not valid
- config-impossible: the configuration file cannot
be applied (internal error, or file corrupted)
- config-internal-error: internal error detected while
checking the configuration file.
- config-applied-ok: the configuration file is valid
and a reset is not mandatory."


 
 