Description:
|
tigRestartReason OBJECT-TYPE
SYNTAX INTEGER {
power (1),
reset-button (2),
watchdog (3),
config-fail (4),
other (5),
double-bus-fault (6),
fatal-exception (7),
reboot-command (8)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Informs the NMS why the Tiger most recently restarted:
power - due to a power failure
reset-button - someone pushed the reset button
watchdog - the internal watchdog timer forced a reset
config-fail - there was a catastrophic failure in the configuration file causing a system reset.
('tigConfigFile' informs you which config file is currently being used)
other - someother unknown reason. (these should never occur)
double-bus-fault - a invalid address was being reference while the exception handler for a bus-fault
exception (an invalid address was referenced) was being executed.
fatal-exception - a fatal software exception occurred inside Tiger
reboot-command - a user issued a 'reboot' command on a console"
|
|
|
|
|
|