Description:
|
saHpiDomainAlarmAcknowledged OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use this columnar object to acknowledge a specific Alarm.
An HPI SNMP Manager acknowledges an alarm to indicate
that it is aware of the alarm and to influence
platform-specific alarm annunciation that may be
provided by the implementation. Typically, an
implementation ignores acknowledged alarms when
announcing an alarm on annunciation devices such as
audible sirens and dry contact closures. However,
An acknowledged alarm will have the Acknowledged field
in the alarm entry set to True.
DomainAlarms are acknowledged by one of two ways:
a single alarm entry by DomainAlarmId regardless of
severity or as a group of alarm entries by Severity
regardless of DomainAlarmId.
To acknowledge all alarms contained within the DAT,
set the Severity parameter to allSeverities(256),
and set the DomainAlarmId parameter to
SAHPI_ENTRY_UNSPECIFIED.
To acknowledge all alarms of a specific severity
contained within the DAT, set the Severity parameter
to the appropriate value, and set the DomainAlarmId
parameter to SAHPI_ENTRY_UNSPECIFIED.
To acknowledge a single alarm entry, set the
DomainAlarmId parameter to a value
other than SAHPI_ENTRY_UNSPECIFIED. The DomainAlarmId
must be a valid identifier for an alarm entry present
in the DAT at the time of the function call.
If an alarm has been previously acknowledged,
acknowledging it again has no effect. However,
this is not an error.
If the DomainAlarmId parameter has a value other than
SAHPI_ENTRY_UNSPECIFIED, the Severity parameter is
ignored.
If the DomainAlarmId parameter is passed as
SAHPI_ENTRY_UNSPECIFIED, and no alarms are present
that meet the requested Severity, this function will
have no effect. However, this is not an error.
SAHPI_ENTRY_UNSPECIFIED is defined as the same value
as SAHPI_FIRST_ENTRY, so using either symbol will
have the same effect. However, SAHPI_ENTRY_UNSPECIFIED
should be used with this function for clarity."
|
|