gponEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF GponEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Event log table.
The device shall maintain this table, to maintain all events had
be reported by the device, including:
1. The event table shall be saved in RAM memory and shall be flushed
when OLT restarts.
2. The event log table shall support no less than 200 entries. When
the event log table is full, the oldest entry in the table shall be
removed first.
3. When OLT is configured with control module redundancy, active controller
shall automatically synchronize the events in event log table b/w active
and standby."
|
|
|
|
|
|