Main page
OID Repository
https://oid-base.com
Display OID:

{iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 1714 raid(1) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}

luDevStatus(13)

 
 

OID description



 
OID: (ASN.1 notation)
(dot notation)
(OID-IRI notation)

Description:

luDevStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical unit device status flags
Power Supply:
BIT 0 - CLEAR: Power supply functioning normally.
SET: Power supply malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Power supply is ON.
SET: Power supply is OFF.
BIT 7 - CLEAR: Power supply IS present.
SET: Power supply is NOT present.
== 0xff - Status unknown.
Fan:
BIT 0 - CLEAR: Fan functioning normally.
SET: Fan malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Fan is ON.
SET: Fan is OFF.
BIT 7 - CLEAR: Fan IS present.
SET: Fan is NOT present.
== 0xff - Status unknown.
Temperature Sensor:
BIT 0 - CLEAR: Temp. sensor functioning normally.
SET: Temp. sensor malfunctioning.
BIT 1 - 3: If == 0, Temp. within safe range.
If == 2, Cold Temp. Warning.
If == 3, Hot Temp. Warning.
If == 4, Cold Temp. Limit Exceeded.
If == 5, Hot Temp. Limit Exceeded.
BIT 6 - CLEAR: Temp. Sensor is Activated.
SET: Temp. Sensor is NOT Activated.
BIT 7 - CLEAR: Temperature sensor IS present.
SET: Temperature sensor is NOT present.
== 0xff - Status unknown.
UPS:
BIT 0 - CLEAR: Unit functioning normally.
SET: Unit malfunctioning.
BIT 1 - CLEAR: AC Power present.
SET: AC Power NOT present.
BIT 2 - 3: If == 0, battery fully charged.
If == 1, battery not fully charged.
If == 2, battery charge critically low.
If == 3, battery completely drained.
BITS 4-5 - Reserved (Set to 0).
BIT 6 - CLEAR: UPS is ON.
SET: UPS is OFF.
BIT 7 - CLEAR: UPS IS present.
SET: UPS is NOT present.
== 0xff - Status unknown.
Battery:
BIT 0 - CLEAR: Battery functioning normally.
SET: Battery malfunctioning.
BIT 1 - CLEAR: Battery charging OFF (or trickle).
SET: Battery charging ON.
BIT 2 - 3: If == 0, battery fully charged.
If == 1, battery not fully charged.
If == 2, battery charge critically low.
If == 3, battery completely drained.
BITS 4-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Battery-backup is enabled.
SET: Battery-backup is disabled.
BIT 7 - CLEAR: Battery IS present.
SET: Battery is NOT present.
== 0xff - Status unknown.
Cache-Data-Backup Flash Device:
BIT 0 - CLEAR: Flash Device functioning normally.
SET: Flash Device malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Flash Device is enabled.
SET: Flash Device is disabled.
BIT 7 - CLEAR: Flash Device IS present.
SET: Flash Device is NOT present.
== 0xff - Status unknown.
Voltage Sensor:
BIT 0 - CLEAR: Voltage sensor functioning normally.
SET: Voltage sensor malfunctioning.
BIT 1 - 3: Current Voltage Sensor State:
If == 0, Voltage within acceptable range.
If == 2, Low Voltage Warning.
If == 3, High Voltage Warning.
If == 4, Low Voltage Limit Exceeded.
If == 5, High Voltage Limit Exceeded.
BIT 4 - 5: Reserved.
BIT 6 - CLEAR: Voltage Sensor is Activated.
SET: Voltage Sensor is NOT Activated.
BIT 7 - CLEAR: Voltage sensor IS present.
SET: Voltage sensor is NOT present.
== 0xff - Voltage Sensor Status unknown.
Current Sensor:
BIT 0 - CLEAR: Current sensor functioning normally.
SET: Current sensor malfunctioning.
BIT 1 - 3: Current Current Sensor State:
If == 0, Current within acceptable range.
If == 3, Over Current Warning.
If == 5, Over Current Limit Exceeded.
BIT 4 - 5: Reserved.
BIT 6 - CLEAR: Current Sensor is Activated.
SET: Current Sensor is NOT Activated.
BIT 7 - CLEAR: Current sensor IS present.
SET: Current sensor is NOT present.
== 0xff - Current Sensor Status unknown.
Door:
BIT 0 - CLEAR: Door OK.
SET: Door, door lock, or door sensor malfunctioning.
BIT 1 - CLEAR: Door is shut.
SET: Door is open.
BITS 2-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Door lock engaged.
SET: Door lock NOT engaged.
BIT 7 - CLEAR: Door IS present.
SET: Door is NOT present.
== 0xff - Status unknown.
Speaker:
BIT 0 - CLEAR: Speaker functioning normally.
SET: Speaker malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Speaker is ON.
SET: Speaker is OFF.
BIT 7 - CLEAR: Speaker IS present.
SET: Speaker is NOT present.
== 0xff - Status unknown.
Slot:
BIT 0 - CLEAR: Slot sense circuitry functioning normally.
SET: Slot sense circuitry malfunctioning.
BIT 1 - CLEAR: Device in slot has not been marked
'needing replacement' or a replacement
drive has been inserted.
SET: Device in slot has been marked BAD
and is awaiting replacement.
BIT 2 - CLEAR: Slot is activated so that drive can be accessed.
SET: Slot NOT activated.
BITS 3-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Slot is NOT ready for insertion/removal.
SET: Slot is ready for insertion/removal.
BIT 7 - CLEAR: Device inserted in slot.
SET: Slot is empty.
== 0xff - Status unknown.
LED:
BITS 0-5 - Reserved (Set to 0).
BIT 6 - CLEAR: LED is active
SET: LED is inactive
BIT 7 - CLEAR: LED IS present.
SET: LED is NOT present.
== 0xff - Status unknown.
Midplane/Backplane Status:
BITS 0-7 - Reserved (Set to 0).
== 0xff - Status unknown.
Host Board Status:
BITS 0-6 - Reserved (Set to 0).
BIT 7 - CLEAR: Host Board IS present.
SET: Host Board is NOT present.
== 0xff - Status unknown.
Enclosure Drawer Status:
BIT 0 - CLEAR: Enclosre Drawer functioning normally.
SET: Enclosre Drawer malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Enclosure Drawer is closed.
SET: Enclosure Drawer is opened.
BIT 7 - CLEAR: Enclosure Drawer IS present.
SET: Enclosure Drawer is NOT present.
== 0xff - Status unknown.
Enclosure Management Services Controller Status:
BIT 0 - CLEAR: Enclosre Drawer functioning normally.
SET: Enclosre Drawer malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Enclosure Drawer is closed.
SET: Enclosure Drawer is opened.
BIT 7 - CLEAR: Enclosure Drawer IS present.
SET: Enclosure Drawer is NOT present.
== 0xff - Status unknown."



Classification:

MIB object for network management

 
See classes of OIDs

Note to implementers:




 
 
Short link:


Parent OID: luDevEntry(1) First sibling OID: luDevTabIdx(1) Previous sibling OID: luDevIDNum(12)