rmonAlarmInterval OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaValue
sampling - the interval should be set short enough
that the sampled variable is very unlikely to
increase or decrease by more than 2^31 - 1 during
a single sampling interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
|
|