Description:
|
lldpLocManAddrLen OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total length of the management address subtype and the
management address fields in LLDPDUs transmitted by the
local LLDP agent.
The management address length field is needed so that the
receiving systems that do not implement SNMP will not be
required to implement an iana family numbers/address length
equivalency table in order to decode the management adress."
REFERENCE
"IEEE 802.1AB-2005 9.5.9.2"
|
|
|