evmaskSend OBJECT-TYPE
SYNTAX INTEGER {off(0), minimal(1), default(3), all(7)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether alarm/warning/audit events are
to be sent to the Event Service. The allowed
values are :
off(0) - no events are sent to EVS.
minimal(1) - only alarm type events
sent to EVS.
default(3) - alarm and warning type
events sent to EVS.
all(7) - alarm, warning and audit
type events sent to EVS."