Description:
|
gpidGeneralEngineFailure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This status indicator for a print engine failure
indicating which print engine failure occured.
This failure may be transient merely requiring the
printer to be turned off and on. Or could require
service support. Each printer will use its own
enumerations. For instance, Wren has specified:
enging-OK(-1),
blackCartridgeMovementError(1),
cyanCartridgeMovementError(2),
magentaCartridgeMovementError(3),
yellowCartridgeMovementError(4),
tonerCartridgeCoolingFanError(5),
scannerMotorUnlocked(10),
laserPowerDownError(11),
lSyncOver(12),
lSyncShort(13),
chargerError(20),
asychronousOPC(21),
opcPositionError(22),
intermediateTransferRollerMovementError(30),
cleaningBladeMovementError(31),
paperTransferRollerMovementError(33),
fuserLowTemperature(40),
fuserHighTemperature(41),
fuserThermistorOpen(42),
powerSupplyCoolingFanError(50),
ozoneFanError(51),
sleeveMotorUnlocked(61),
transportMotorUnlocked(62),
mainMotorUnlocked(63),
ROMCheckSumError(70),
SRAMCheckError(71),
for its enumerations."
|
|
|
|