Description:
|
cienaCesOamErrFrameSecsSummaryThreshold OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "errored frame seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of errored frame seconds that must occur for this
event to be triggered. The default value is one errored frame
second.
If cienaCesOamErrFrameSecsSummaryThreshold frame errors occur
within a window of cienaCesOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window."
REFERENCE
"[802.3ah], 30.3.6.1.40"
|
|
|
|