Description:
|
cienaCesOamErrFrameWindow OBJECT-TYPE
SYNTAX Unsigned32 (10..600)
UNITS "tenths of a second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time (in 100ms increments) over which the
threshold is defined. The default value is 10 (1 second).
If cienaCesOamErrFrameThreshold frame errors occur within a window
of cienaCesOamErrFrameWindow seconds (measured in tenths of
seconds), an Event Notification OAMPDU should be generated with
an Errored Frame Event TLV indicating the threshold has been
crossed in this window."
REFERENCE
"[802.3ah], 30.3.6.1.36"
|
|
|
|