|
|
Description:
|
brzaccVLMaxContentionWindow OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable to SU and AU.
For units bearing SW version 4.0 and above applicable to
BreezeNET-B products, for previous SW versions not applicable
to BreezeNET-B products.
The maximum value to be used by the contention window calculation
algorithm.
Value must be power of 2 minus 1 (7,15,31...)
Range: 7 to 1023."
|
|
Disclaimer: The owner of this site does not warrant or assume any liability or responsibility for the accuracy, completeness, or usefulness of any information available on this page (for more information, please read the complete disclaimer).
All rights reserved © 2007-2024 |