Description:
|
dcmPhysicalLogicalIOControl OBJECT-TYPE
SYNTAX INTEGER {notSupported(1), enable(2), disable(3), reset(4), suspend(5)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows an application to enable, disable,reset or suspend a physical IOchannel. The value of this object represents the last user-selected control.
An application may want to enable/disable an IO channel for diagnosticpurposes. If the requested operation is not supported by the specified IOchannel, this value shall be set to 'notSupported'."
|
|
|
|
|
|