Description:
|
outputControl OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> Output control activates and deactivates individual discrete
outputs as outlined below:
Byte1
Bit7 0 = NOT SELECT, 1 = SELECT designates the control of Output
8 (MSB),
Bit6 0 = NOT SELECT, 1 = SELECT designates the control of Output
7,
Bit5 0 = NOT SELECT, 1 = SELECT designates the control of Output
6,
Bit4 0 = NOT SELECT, 1 = SELECT designates the control of Output
5,
Bit3 0 = NOT SELECT, 1 = SELECT designates the control of Output
4,
Bit2 0 = NOT SELECT, 1 = SELECT designates the control of Output
3,
Bit1 0 = NOT SELECT, 1 = SELECT designates the control of Output
2,
Bit0 0 = NOT SELECT, 1 = SELECT designates the control of Output
1(LSB),
Byte2
Bit7 0 = OFF, 1 = ON for the desired active state of discrete Output 8(MSB),
Bit6 0 = OFF, 1 = ON for the desired active state of discrete Output 7,
Bit5 0 = OFF, 1 = ON for the desired active state of discrete Output 6,
Bit4 0 = OFF, 1 = ON for the desired active state of discrete Output 5,
Bit3 0 = OFF, 1 = ON for the desired active state of discrete Output 4,
Bit2 0 = OFF, 1 = ON for the desired active state of discrete Output 3,
Bit1 0 = OFF, 1 = ON for the desired active state of discrete Output 2,
Bit0 0 = OFF, 1 = ON for the desired active state of discrete Output 1(LSB).
Please note that user defined discrete inputs may reduce interoperability of
the device. When read, this object returns last value written.
<DescriptiveName> CctvSwitch.outputControl:text
<DataConceptType> Data Element"
|
|
|
|
|
|