Description:
|
sensorSystemReset OBJECT-TYPE
SYNTAX INTEGER {restart(1), reinitialize(2), shortDiagnostics(3),
fullDiagnostics(4), commandComplete(255)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> This object commands the entire sensor system to reset. Reading a value other than 255 indicates the presence of a pending or executing command. A write to this object is not allowed unless the current value is 255. The reset commands are described as follows:
Value Meaning
1 Restart command shall cause the unit to enter restart state and go through a complete shut-down and start-up process;
2 Reinitialization commands hall cause the unit to flush all volatile memory and reinitialize all settings to their default values;
3 Short diagnostics command shall cause the unit to go through an abbreviated vendor specific diagnostic routine which may be the same as full diagnostics for some vendors;
4 Full diagnostics shall cause the unit to go through a complete vendor specific diagnostic routine which may be the same as short diagnostics for some vendors;
5..128 Reserved for future use;
255 Command complete shall be the default-state for which writing causes no action.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.4.1.1"
|
|
|
|
|
|