Description:
|
dmsIllumManLevel OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> Indicates the desired value of the Brightness Level as a value ranging from 0 to the value of the dmsIllumNumBrightLevels-object when under manual control.
When the dmsIllumControl object is set to a value of 'manualDirect (5)' then the maximum value that this object can have is the total levels of brightness that this device supports. A user can calculate the direct manual light output as (65535 * (dmsIllumManLevel object value / dmsIllumNumBrightLevels object value)).
When the dmsIllumControl object is set to a value of 'manualIndexed (6)' then the maximum value that this object can be set to is the number of rows defined in the table of the dmsIllumBrightnessValues object.
If the device supports version 1 and the dmsIllumControl object is set to a value of 'manual (4)', then the deployment could be either (contact your vendor to determine which way is implemented)
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.7.6"
|
|
|
|
|
|