rmcTBCMinMeterRateCtrl OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the operational minimum metering rate. This object is used to
control the entry, while the rmcTBCMinMeterRateStatus-object indicates the
status.
This value shall be less than or equal to the rmcTBCMaxMeterRateCtrl-object.
This value shall be expressed in 1-vph increments.
A suggested usable range is 0, 120 to 1800.
A value of zero (0) indicates this parameter shall not be used.
<Unit> vehicles per hour
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.5.6.1.7"
REFERENCE
"See Clause A.3.1"
|
|
|
|
|
|