Description:
|
rmcTBRateCtrl OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the metering rate that to be used if the metered lane is commanded
by timebase control and the rmcImplementAction-object has a value of
'fixedRate'. This object is used to control the entry, while the
rmcTBRateStatus-object indicates the status.
This value shall be expressed in 1-vph increments.
A suggested usable range is 120 to 1800.
<Unit> vehicles per hour
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.5.6.1.5"
REFERENCE
"See Clause A.3.1"
|
|
|
|
|
|