Description:
|
rmcMLSpeedTrapSpacingV2 OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the spacing between the leading and trailing detector measured
from upstream edge to upstream edge of the detectors.
This value shall be expressed in 0.01-meter increments (i.e, 400 = 4.00
meters).
A suggested usable range is 200 to 1500.
A value of zero (0) shall inhibit the calculation of speed.
<Unit> hundredth of meter
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.2.4.1.13"
REFERENCE
"See Clause A.2.1"
DEFVAL {61}
|
|
|
|
|
|