Description:
|
rmcMLFlowBasedNoActivityTable OBJECT-TYPE
SYNTAX SEQUENCE OF RmcMLFlowBasedNoActivityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing the configuration information for an entry in the
Mainline Flow-based No Activity Table. The purpose of this table is to
define the duration for the flow-based no activity diagnostic test. The
duration will vary with the Average Station Flow Rate.
Flow-based No Activity Threshold value in the first entry shall be the
maximum threshold.
If the value of the rmcAverageFlowRate-object is less than the value of the
rmcFlowRateNoActivityThreshold-object in this entry row and greater than the
value in the following entry, then the Flow-based No Activity Duration in that
entry shall be used.
If the value of the rmcAverageFlowRate-object is less than the value of the
rmcFlowRateNoActivityThreshold-object in the last entry, then the Flow-based
No Activity Duration of the last entry shall be used.
If the value of the rmcAverageFlowRate-object is greater than the maximum
value of the rmcFlowRateNoActivityThreshold-object in the table, then the
Mainline Flow-based No Activity test shall be disabled.
The first instance of the rmcFlowRateNoActivityThreshold-object whose value is
zero indicates the end of the valid table contents. Rows prior to the end of
the valid rows that contain a value of zero (0) for the
rmcFlowBasedNoActivityDuration-object indicate that this row shall NOT be used
for flow-based no activity testing.
Additionally, the following rules shall be used when configuring this table:
- All rmcFlowRateNoActivityThreshold-object entries in the table shall be
decreasing for increasing indices.
- All rmcFlowBasedNoActivityDuration-object entries in the table shall be
non-decreasing for increasing indices.
- if the value of the rmcNumFlowRateLanes-object is '', then the
rmcFlowRateNoActivityDuration-object shall have a value of ''.
<Table Type> static.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.2.11"
|
|
|
|
|
|