Description:
|
rmcCommRefreshThreshold OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> This is an RMC parameter that is being used for each metered
lane. If no successful SET command communication has been issued to the
rmcCommActionMode-object of a metered lane for the time indicated in this
threshold, the value of the rmcCommActionStatus-object for that metered lane
shall be set to 'noComm'.
This value shall be expressed in 1-second increments.
A suggested usable range is 0, 20 to 14400.
A value of zero (0) shall inhibit communications refresh timing.
<Unit> second
<Object Identifier> 1.3.6.1.4.1.1206.4.2.2.1.1"
REFERENCE
"see Clause A.3"
DEFVAL {0}
|
|
|
|
|
|