Description:
|
prsBusy OBJECT-TYPE
SYNTAX TrueFalse
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is used to indicate to a CO that the PRS is initializing or otherwise processing and, when TRUE, the information included with it in a prsServiceRequest response is not valid. It is used to synchronize exchanges between a PRS and CO.
When the CO is acting as manager and the PRS is acting as an agent, prsBusy is set TRUE when the CO performs a SetRequest prsServiceRequest.
When the PRS is acting as a manager and the CO is acting as the agent, prsBusy is set TRUE when the CO responds to a GetRequest prsServiceRequest from the PRS with coBusy set to FALSE."
|
|
|
|
|
|