Description:
|
trapAggregationTime OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> maximum time (in seconds) that this trap can wait for
transmission while being aggregated within a trap chain (for
noack_Aggr and ack_Aggr traps only). The value of zero (0) indicates
immediate trap chain transmission. The first trap with a mode
specifying 'timed' aggregation starts this timer. The timer is
reset when the trap chain is sent. The aggregation
timers for each entry in the trap chain time concurrently and the
first one to expire causes the entire trap chain to be sent to the
management station.
(Note that this is larger than 8 bits to allow aggregation times
to support 5 minutes and longer).
<Object Identifier> 1.3.6.1.4.1.1206.4.1.4.1.7.1.3"
REFERENCE
"NTCIP 1103 v03 Section 6.2.4"
DEFVAL {0}
|
|
|
|
|
|