Description:
|
dynamicObjectPersistence OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> The maximum power outage time in minutes thatmay occur before all STMP dynamic object definitions in adevice shall be invalidated. If this object is set to zerothen the existing dynamic object definintions shall beinvalidated on device power up. If this object is set toits maximum value (65535) then the existing dynamic objectdefinitions shall nominally persist for an infinite period(in practice this will be limited by the non-volatile memorycapabilities of the device) This object shall not beinvalidated due to power outages of any duration. A device
that supports STMP dynamic objects shall support this object.
<Object Identifier> 1.3.6.1.4.1.1206.4.1.2.2.1"
DEFVAL {65535}
|
|
|
|
|
|