Description:
|
recordingStatus OBJECT-TYPE
SYNTAX INTEGER {available(1), preevent(2), triggered(3), complete(4)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"<Definition>The value of this object reflects the state of the
recording located in this row.
Value Description
available this row is available for a new recording to be initiated
for this recording class. When a recording is cleared, the
value is set to available
preevent the recording defined by recConfigID is collecting
pre-event record entries. Note: If the trigger point is
set to zero (0) percent or the trigger condition is already
satisfied when the recConfigID is configured, then the
value transitions straight from available to triggered.
triggered the recording defined by recConfigID has triggered and is now
collecting post event records. If the trigger point was set
to 100 percent, then the value transitions straight from
preevent to complete. If a recording was triggered and the
device experienced a power failure, then upon power
restoration it shall change the value to complete.
Triggered recordings shall survive a power outage.
complete the recording defined by recConfigID is now complete (i.e.
collected all of its post events) and ready for retrieval.
Completed recordings shall survive a power outage.
<Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.9.1.6"
|
|
|
|
|
|