Description:
|
recConfigSamplePeriod OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> This object contains the sample period for recordings
collected at specified by this configuration. The sample period is
expressed in units of 0.1 milliseconds. Allowable sample periods
are restricted to a value of zero (0) or
(recMinSamplePeriod + recSamplePeriodResolution * n)
where n is integer, 0 <= n, and
n <= (recMaxSamplePeriod-recMinSamplePeriod)/recSamplePeriod Resolution
If the value is zero (0), then the samples are not collected on a
periodic basis, but rather a new sample is collected whenever the
value of the object specified by recConfigSampleOID changes (i.e.
similar to event log 'on-change' mode). A set to any other value
results in a badValue response.
<Object Identifier> 1.3.6.1.4.1. 1206.4.1.1.7.9.7.1.9"
DEFVAL {1000}
|
|
|
|
|
|