Description:
|
ipeFsUpdateFileUpdateList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Definition of update slot number.
Form of file list:
When downloading it to ODU/FPGA/MDPRM, the forwarding site slot
number is enumerated by a comma end.
Ex) 0,5,1,6,10...
The slot number of relating MODEM and fpga must set the slot
number of
Option Card to odu and mdprm according to inventory
information.
The slot number to which the current state can be set becomes the
following.
iPASO200 iPASO400,1000
0 : MainBoard or SLOT0
1 : MODEM1 or SLOT1
2 : MODEM2 or SLOT2
3 : Option Card or SLOT3
:
33: ODU1
34: ODU2
35: ODU3
:
*Pertinent details: ipeFsUpdateFileDetail"
|
|
|