Description:
|
bcsSimScsEcmgRedundancyConfigManualSwitchBack OBJECT-TYPE
SYNTAX ManualSwitchBackTYPE
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When autoswitchback is enabled manual switch back is
notActive.When manual switch back Button get pressed Manual switch back state get changed from manualSwitchBackNotInProgress(1) to
(2)manualSwitchBack.Then the programs (which were taken away earlier from this ECMG upon its failure)will be switched back to it.
Once the switchback progress get finished ,manual switch back state changed to (1) manualSwitchBackNotInProgress."
|
|
|
|