Description:
|
bcsSimScsEcmIdInitial OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each ECM ID and Super CAS ID combination in the Simulcrypt
system must be globally unique. To simplify configuration,
each SCS is given a starting ECM ID to assign to the first
ECM stream it creates. The number is incremented as new
ECM streams are created. Each SCS must be configured with a
different value. The initial values should be spaced
sufficiently to prevent overlapping. Recommended spacing
is 128.
SEM Note:
Once written, a save must be performed via the semSaveConfig
parameter and the SEM must be rebooted for the change to take
effect."
|
|
|
|