Description:
|
scanner-lamp-gain-value OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides PWM and analog gain for the color channels. The range
will vary based on scan mode. The device specific POS should
describe the valid range. The format is the following:
PWM value; red analog gain; green analog gain; blue analog
gain.
Additional information:
The range will vary based on scan mode. The values
will differ from those of San Diego. The initial value
can be obtained at the start of warmup and the final
value can be obtained at the end of warmup. The warmup period is about
2 minutes. The format is the following PWM value; red analog gain;
green analog gain; blue analog gain;. The valid values for PWM value
are 580 - 730 and the valid values for analog gains are 1.00-5.80.
The gains are reported with accuracy to 2 decimal places.
A sample return value would be '584;1.00;1.34;1.00;'"
|
|
|