Description:
|
scanner-reference-position OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides 3 pairs of x,y coordinates within a specified range of
the calibrate reference position. The device specific POS
should specify the valid ranges. The format is the following:
'x;y;x;y;x;y'
Additional information:
Provides x,y coordinates within 1/300 of a line of the
calibrate reference position. The 3 locations in order that are
reported are the 1st Reference Mark, the 2nd Reference Mark, and
the Document Origin. A sample return value would be
80,471;2523,2914;80,471;1;34326;27,32;193;35748;28,27;194;0,0;0;0;0;0;0;0;0,0;0;0;0;0;0;0;0,0;0;0,0;0;0;0
The extra 0's on the end are used specifically to gather information during
the cimation process."
|
|
|