Description:
|
hpicfSyslogAlertTransmitInterval OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the transmission interval in seconds for
sending alerts in Syslog messages. Only one Syslog
message is allowed for transmission within this time
interval. Default value is 0, indicating there is no
rate limit for alerts transmission."
DEFVAL {0}
|
|
|