Description:
|
hpicfIpSlaThrType OBJECT-TYPE
SYNTAX INTEGER {immediate(1), consecutive(2), aggregated(3)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Configure threshold type to trigger action. When a trap/log
has to be generated each time the threshold is breached,
immediate threshold type can be used. The Consecutive threshold
type generates traps/logs when the threshold is violated a
certain number of times This value is not applicable when
hpicfIpSlaThrMetricType is set to testCompletion. The aggregated
threshold type is used to generate traps/logs for aggregated probes."
|
|
|