Description:
|
fcFxPortPhysOperStatus OBJECT-TYPE
SYNTAX INTEGER {
online (1), -- Login may proceed
offline (2), -- Login cannot proceed
testing (3), -- port is under test
linkFailure (4) -- failure after online/testing
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational status of the FxPort. The
testing(3) indicates that no operational frames can be
passed. If fcFxPortPhysAdminStatus is offline(2) then
fcFxPortPhysOperStatus should be offline(2). If
fcFxPortPhysAdminStatus is changed to online(1) then
fcFxPortPhysOperStatus should change to online(1) if the
FxPort is ready to accept Fabric Login request from the
attached NxPort; it should proceed and remain in the link-
failure(4) state if and only if there is a fault that
prevents it from going to the online(1) state."
|
|
|
|
Information:
|
Automatically extracted from IETF RFC 2837.
|
|
|
|