Description:
|
tcpMIBCompliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for systems that implement TCP.
A number of INDEX objects cannot be
represented in the form of OBJECT clauses in SMIv2 but
have the following compliance requirements,
expressed in OBJECT clause form in this description
clause:
-- OBJECT tcpConnectionLocalAddressType
-- SYNTAX InetAddressType { ipv4(1), ipv6(2) }
-- DESCRIPTION
-- This MIB requires support for only global IPv4
-- and IPv6 address types.
--
-- OBJECT tcpConnectionRemAddressType
-- SYNTAX InetAddressType { ipv4(1), ipv6(2) }
-- DESCRIPTION
-- This MIB requires support for only global IPv4
-- and IPv6 address types.
--
-- OBJECT tcpListenerLocalAddressType
-- SYNTAX InetAddressType { unknown(0), ipv4(1),
-- ipv6(2) }
-- DESCRIPTION
-- This MIB requires support for only global IPv4
-- and IPv6 address types. The type unknown also
-- needs to be supported to identify a special
-- case in the listener table: a listen using
-- both IPv4 and IPv6 addresses on the device.
--"
MODULE -- this module
MANDATORY-GROUPS { tcpBaseGroup, tcpConnectionGroup,
tcpListenerGroup }
GROUP tcpHCGroup
DESCRIPTION
"This group is mandatory for systems that are capable
of receiving or transmitting more than 1 million TCP
segments per second. 1 million segments per second will
cause a Counter32 to wrap in just over an hour."
OBJECT tcpConnectionState
SYNTAX INTEGER { closed(1), listen(2), synSent(3),
synReceived(4), established(5),
finWait1(6), finWait2(7), closeWait(8),
lastAck(9), closing(10), timeWait(11) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support for the value
deleteTCB (12)."
|
|
|
|
Information:
|
Automatically extracted from IETF RFC 4022.
|
|
|
|