Description:
|
mdmCCCallSetUpFailTimer OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the amount of time, in seconds,
that the modem shall allow between either answering a call
(automatically or manually) or completion of dialing, and
establishment of a connection with the remote modem. If no
connection is established during this time, the modem
disconnects from the line and returns a result code
indicating the cause of the disconnection. In TIA-602, this
is controlled by the value in the S7 register."
REFERENCE "V.58 callSetUpFailTimer"
DEFVAL { 30 }
|
|
|
|
Information:
|
Automatically extracted from IETF RFC 1696.
|
|
|
|