|
|
Description:
|
mdmCCCallSetUpFailTimer OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the amount of time, in seconds, that the modem shall allow between either answering a call (automatically or manually) or completion of dialing, and establishment of a connection with the remote modem. If no connection is established during this time, the modem disconnects from the line and returns a result code indicating the cause of the disconnection. In TIA-602, this is controlled by the value in the S7 register."
REFERENCE
"V.58 callSetUpFailTimer"
DEFVAL {30}
|
|
|
|
Information:
|
Automatically extracted from IETF RFC 1696.
|
|
|
|