Description:
|
atmMIBCompliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities including networks which have ATM and AAL5 interfaces."
MODULE -- this module
-- ****** Interface and Traffic Descriptor Support ***
MANDATORY-GROUPS {atmInterfaceConfGroup2, atmTrafficDescrGroup2 }
OBJECT atmInterfaceMaxVpcs
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmInterfaceMaxVccs
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmInterfaceMaxActiveVpiBits
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. At the ATM UNI the maximum number of active VPI bits configured for use ranges from 0 to 8 only. Implementations may support smaller ranges."
OBJECT atmInterfaceMaxActiveVciBits
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. Implementations may support smaller ranges."
OBJECT atmInterfaceIlmiVpi
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmInterfaceIlmiVci
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmInterfaceMyNeighborIpAddress
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmInterfaceMyNeighborIfName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmInterfaceSubscrAddress
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrParamIndexNext
DESCRIPTION
"This object is only required for systems that support the creation of entries in the atmTrafficDescrParamTable."
OBJECT atmTrafficDescrType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrParam1
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrParam2
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrParam3
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrParam4
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrParam5
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmServiceCategory
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmTrafficDescrRowStatus
SYNTAX INTEGER {active(1)}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)."
OBJECT atmTrafficFrameDiscard
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- ****** DS3 PLCP Support **************************
GROUP atmInterfaceDs3PlcpGroup
DESCRIPTION
"This group is mandatory only for those
ATM interfaces which implement the
DS3 PLCP layer."
-- ****** TC Sublayer Support *************************
GROUP atmInterfaceTCGroup
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement the
TC Sublayer."
-- ****** VPC Support *******************************
GROUP atmVpcTerminationGroup2
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement ATM VPLs that terminate VPCs (i.e., ones which are NOT cross-connected to other VPLs)."
GROUP atmVplCrossConnectGroup
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement ATM VPLs that are not associated with VCLs and are cross-connected to other VPLs for VPCs."
GROUP atmVpPvcCrossConnectGroup
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement ATM VPLs that are not associated with VCLs and are cross-connected to other VPLs for permanent VPCs (i.e., PVCs). This group is not used to crossconnect a PVC with an SVC to form a Soft PVC."
OBJECT atmVplAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVplReceiveTrafficDescrIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVplTransmitTrafficDescrIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVplRowStatus
SYNTAX INTEGER {active(1)}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)."
OBJECT atmVplCastType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVplConnKind
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVpCrossConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVpCrossConnectRowStatus
SYNTAX INTEGER {active(1)}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)."
-- ****** VCC Support *******************************
GROUP atmVccTerminationGroup2
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement ATM VCLs that terminate VCCs (i.e., ones which are NOT cross-connected to other VCLs)."
GROUP atmVclCrossConnectGroup
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement ATM VCLs that are cross-connected to other VCLs for VCCs."
GROUP atmVcPvcCrossConnectGroup
DESCRIPTION
"This group is mandatory only for those ATM interfaces which implement ATM VCLs that are cross-connected to other VCLs for permanent VCCs (i.e., PVCs). This group is not used to crossconnect a PVC with an SVC to form a Soft PVC."
OBJECT atmVclAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVclReceiveTrafficDescrIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVclTransmitTrafficDescrIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVccAalType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVclRowStatus
SYNTAX INTEGER {active(1)}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)."
OBJECT atmVclCastType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVclConnKind
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVcCrossConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVcCrossConnectRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)."
-- ****** AAL5 Support ******************************
GROUP aal5VccGroup
DESCRIPTION
"This group is mandatory for the AAL5 virtual connections only."
OBJECT atmVccAal5CpcsTransmitSduSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVccAal5CpcsReceiveSduSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVccAal5EncapsType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
|
|
|
Information:
|
Automatically extracted from IETF RFC 2515.
|
|