Description:
|
atmSigSupportClgPtySubAddr OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept and transfer the Calling
Party Subaddress Information Element from the calling party to
the called party. Calling party subaddress information shall
only be transferred to the called party if calling party number
delivery is enabled (i.e., atmSigSupportClgPtyNumDel =
'enabled(1)'. The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
|
|
|
Information:
|
Automatically extracted from IETF RFC 3606.
|
|